12.5 kHz high shelf
Lifts or drops everything above f0 by a fixed amount and leaves the bottom flat. Solved at 5 sample rates, with the poles, the real −3 dB point and the word length it stops working at.
Magnitude response at 48 kHz
Every vertex is 20·log₁₀|H(ejω)| evaluated on the unit circle — not a sketch of the filter's shape. Shelves fix the slope at S = 1, so there is no Q family to draw; the faint traces are the gain sweep.
Gain at f0 (12.5 kHz)
+3.00 dB
exact at every sample rate — the bilinear transform maps this value, not just the frequency
Pole radius at 48 kHz
0.4303221
conjugate pair at ±108.78°, 0.570 from the circle
−3 dB point
12486.4 Hz
0.999× f0 at Q = 0.7071
16-bit fixed point
holds
largest pole 0.4303262 in Q1.14
Coefficients, at every sample rate
The cookbook computes w₀ = 2πf₀/Fs, so the same filter is a different set of numbers at every rate. Rates whose Nyquist limit is at or below 12.5 kHz are absent because the filter does not exist there — equivalently, the f₀/Nyquist column never reaches 100%. That is why this table is 5 rows and a 20 Hz page is 8.
| Sample rate | b0 | b1 | b2 | a1 | a2 | Pole r | f₀/Nyquist |
|---|---|---|---|---|---|---|---|
| 32 kHz | 1.175315 | 1.080406 | 0.382119 | 1.199380 | 0.438460 | 0.662163 | 78.1% |
| 44.1 kHz | 1.353846 | 0.061882 | 0.232783 | 0.442164 | 0.206348 | 0.454256 | 56.7% |
| 48 kHz | 1.394022 | -0.174821 | 0.243054 | 0.277078 | 0.185177 | 0.430322 | 52.1% |
| 96 kHz | 1.649840 | -1.734897 | 0.617557 | -0.736700 | 0.269199 | 0.518844 | 26.0% |
| 192 kHz | 1.808195 | -2.745062 | 1.109358 | -1.332770 | 0.505261 | 0.710817 | 13.0% |
const float b0 = 1.39402180f, b1 = -0.17482090f, b2 = 0.24305386f;
const float a1 = 0.27707767f, a2 = 0.18517710f; // a0 == 1What word length this filter survives
The fixed-point rows round all five coefficients to one shared scale, which is what a q15/q31 biquad section does with its post-shift.Pole radius is solved from the quadratic, not taken as √|a₂| — once rounding pushes the poles onto the real axis those two disagree, and the convenient one reports a comfortable margin on a filter that has already left the unit circle. Error is the worst deviation from float64 across frequencies where the response is within 40 dB of its own peak; below that it is measuring the −200 dB floor.
| Word format | Q format | Largest pole | √|a₂| says | Stable | Worst error in band |
|---|---|---|---|---|---|
| float64 | — | 0.4303221 | 0.4303221 | yes | reference |
| float32 | — | 0.4303221 | 0.4303221 | yes | 0.0000 dB |
| 32-bit fixed | Q1.30 | 0.4303221 | 0.4303221 | yes | 0.0000 dB |
| 24-bit fixed | Q1.22 | 0.4303221 | 0.4303221 | yes | 0.0000 dB |
| 16-bit fixed | Q1.14 | 0.4303262 | 0.4303262 | yes | 0.0002 dB |
What gain does at 12.5 kHz
A shelf reaches half its dB gain at f₀ — exactly half, at every sample rate — and its full gain on the far side.
| Gain | At f₀ | b0 | a1 | a2 | Pole r |
|---|---|---|---|---|---|
| -12 dB | −6.00 dB | 0.514440 | -0.324712 | 0.190274 | 0.436204 |
| -6 dB | −3.00 dB | 0.717349 | -0.125408 | 0.174354 | 0.417558 |
| -3 dB | −1.50 dB | 0.846980 | -0.024426 | 0.171678 | 0.414341 |
| +3 dB | +1.50 dB | 1.180665 | 0.177380 | 0.177140 | 0.420881 |
| +6 dB | +3.00 dB | 1.394022 | 0.277078 | 0.185177 | 0.430322 |
| +12 dB | +6.00 dB | 1.943863 | 0.471401 | 0.211133 | 0.459492 |
Questions this filter answers
What are the biquad coefficients for a 12.5 kHz high-shelf filter at 48 kHz?
b0 = 1.394022, b1 = -0.174821, b2 = 0.243054, a1 = 0.277078, a2 = 0.185177, with a0 normalised to 1 — the RBJ Audio EQ Cookbook form at Q = 0.7071 and +6 dB of gain. Every other sample rate in the table above gives different numbers for the same filter, because w0 = 2πf0/Fs and every cosine and sine downstream of it moves.
Is a 12.5 kHz high-shelf filter stable in 16-bit fixed point?
Yes. Rounding the five coefficients to a shared 1.14 scale leaves the largest pole at 0.4303262, against 0.4303221 exact, and the response drifts by at most 0.000 dB inside the band. 24-bit takes that to 0.0000 dB.
Where is the real −3 dB point of a 12.5 kHz high-shelf filter?
12486.4 Hz, which is 0.999× the 12.5 kHz corner. f0 and the −3 dB point are the same frequency only at Q = 1/√2; this page is designed at Q = 0.7071, and a shelf does not read Q at all — its slope is fixed at S = 1, matching Web Audio's BiquadFilterNode, so the gain sweep above is the family that moves this filter rather than a Q sweep.
How close to the unit circle are the poles of a 12.5 kHz high-shelf filter?
0.4303221 at 48 kHz, as a conjugate pair at ±108.78°. Pole radius rises toward 1 as the corner frequency falls relative to the sample rate — the same filter at 192 kHz sits at 0.7108169 and at 8 kHz it is above Nyquist. That distance is the whole story of the fixed-point table: a pole a few parts in 10⁵ from the circle has nowhere to be rounded to.
The neighbouring corners
One third-octave either side, and the same 12.5 kHz corner as every other filter type.
- Low-pass12.5 kHz
- High-pass12.5 kHz
- Band-pass12.5 kHz
- Notch12.5 kHz
- All-pass12.5 kHz
- Peaking EQ12.5 kHz
- Low shelf12.5 kHz
Method and limits. Coefficients follow the RBJ Audio EQ Cookbook, the bilinear transform of the analog prototype prewarped so the corner lands exactly on f0 — which is why +3.00 dB at 12.5 kHz holds at every sample rate in the table rather than only at low f0/Fs. Shelves fix the slope at S = 1, matching Web Audio's BiquadFilterNode, so Q is not read for those two types. Pole and zero radii are the roots of the quadratic, not sqrt(|a2|). The fixed-point rows model a single shared coefficient scale and no other quantisation: they say nothing about signal-path headroom, limit cycles or the accumulator width your implementation uses, all of which can make a filter that passes this table still misbehave. Nothing on this page is fetched or estimated — it is solved from the type and the frequency in the URL.