8 kHz all-pass
Leaves every magnitude alone and shifts phase, passing through −180° at f0. Solved at 6 sample rates, with the poles, the real −3 dB point and the word length it stops working at.
Magnitude response at 48 kHz
Every vertex is 20·log₁₀|H(ejω)| evaluated on the unit circle — not a sketch of the filter's shape. The faint traces behind it are the same corner at every Q in the sweep below.
Gain at f0 (8 kHz)
0.00 dB
exact at every sample rate — the bilinear transform maps this value, not just the frequency
Pole radius at 48 kHz
0.6290159
conjugate pair at ±56.31°, 0.371 from the circle
−3 dB point
none
the magnitude never falls 3 dB below its own peak inside the band
16-bit fixed point
holds
largest pole 0.6290397 in Q1.14
Coefficients, at every sample rate
The cookbook computes w₀ = 2πf₀/Fs, so the same filter is a different set of numbers at every rate. Rates whose Nyquist limit is at or below 8 kHz are absent because the filter does not exist there — equivalently, the f₀/Nyquist column never reaches 100%. That is why this table is 6 rows and a 20 Hz page is 8.
| Sample rate | b0 | b1 | b2 | a1 | a2 | Pole r | f₀/Nyquist |
|---|---|---|---|---|---|---|---|
| 22.1 kHz | 0.449731 | 0.943683 | 1.000000 | 0.943683 | 0.449731 | 0.670620 | 72.6% |
| 32 kHz | 0.333333 | -0.000000 | 1.000000 | -0.000000 | 0.333333 | 0.577350 | 50.0% |
| 44.1 kHz | 0.375254 | -0.574540 | 1.000000 | -0.574540 | 0.375254 | 0.612580 | 36.3% |
| 48 kHz | 0.395661 | -0.697831 | 1.000000 | -0.697831 | 0.395661 | 0.629016 | 33.3% |
| 96 kHz | 0.600000 | -1.385641 | 1.000000 | -1.385641 | 0.600000 | 0.774597 | 16.7% |
| 192 kHz | 0.770837 | -1.710497 | 1.000000 | -1.710497 | 0.770837 | 0.877973 | 8.3% |
const float b0 = 0.39566104f, b1 = -0.69783052f, b2 = 1.00000000f;
const float a1 = -0.69783052f, a2 = 0.39566104f; // a0 == 1What word length this filter survives
The fixed-point rows round all five coefficients to one shared scale, which is what a q15/q31 biquad section does with its post-shift.Pole radius is solved from the quadratic, not taken as √|a₂| — once rounding pushes the poles onto the real axis those two disagree, and the convenient one reports a comfortable margin on a filter that has already left the unit circle. Error is the worst deviation from float64 across frequencies where the response is within 40 dB of its own peak; below that it is measuring the −200 dB floor.
| Word format | Q format | Largest pole | √|a₂| says | Stable | Worst error in band |
|---|---|---|---|---|---|
| float64 | — | 0.6290159 | 0.6290159 | yes | reference |
| float32 | — | 0.6290159 | 0.6290159 | yes | 0.0000 dB |
| 32-bit fixed | Q1.30 | 0.6290159 | 0.6290159 | yes | 0.0000 dB |
| 24-bit fixed | Q1.22 | 0.6290160 | 0.6290160 | yes | 0.0000 dB |
| 16-bit fixed | Q1.14 | 0.6290397 | 0.6290397 | yes | 0.0000 dB |
What Q does at 8 kHz
f₀ does not move with Q — the −3 dB point does. They are the same frequency only at Q = 1/√2, which is why a Butterworth corner is the one people quote and why every other Q surprises somebody.
| Q | At f₀ | Peak | −3 dB | Pole r | Group delay at f₀ |
|---|---|---|---|---|---|
| 0.5 | 0.00 dB | 0.00 dB @ 12 Hz | — | 0.267949 | 0.048 ms |
| 0.7071 | 0.00 dB | 0.00 dB @ 531 Hz | — | 0.490314 | 0.068 ms |
| 1 | 0.00 dB | 0.00 dB @ 316 Hz | — | 0.629016 | 0.096 ms |
| 2 | 0.00 dB | 0.00 dB @ 86 Hz | — | 0.802529 | 0.192 ms |
| 4 | 0.00 dB | 0.00 dB @ 8.19 kHz | — | 0.897018 | 0.385 ms |
| 10 | 0.00 dB | 0.00 dB @ 8.19 kHz | — | 0.957597 | 0.962 ms |
Questions this filter answers
What are the biquad coefficients for a 8 kHz all-pass filter at 48 kHz?
b0 = 0.395661, b1 = -0.697831, b2 = 1.000000, a1 = -0.697831, a2 = 0.395661, with a0 normalised to 1 — the RBJ Audio EQ Cookbook form at Q = 1.0000. Every other sample rate in the table above gives different numbers for the same filter, because w0 = 2πf0/Fs and every cosine and sine downstream of it moves.
Is a 8 kHz all-pass filter stable in 16-bit fixed point?
Yes. Rounding the five coefficients to a shared 1.14 scale leaves the largest pole at 0.6290397, against 0.6290159 exact, and the response drifts by at most 0.000 dB inside the band. 24-bit takes that to 0.0000 dB.
Where is the real −3 dB point of a 8 kHz all-pass filter?
This type has no −3 dB edge to find: its magnitude response is unity at every frequency, and what f0 marks is the point where the phase passes through −180°. At f0 the response measures 0.00 dB.
How close to the unit circle are the poles of a 8 kHz all-pass filter?
0.6290159 at 48 kHz, as a conjugate pair at ±56.31°. Pole radius rises toward 1 as the corner frequency falls relative to the sample rate — the same filter at 192 kHz sits at 0.8779731 and at 8 kHz it is above Nyquist. That distance is the whole story of the fixed-point table: a pole a few parts in 10⁵ from the circle has nowhere to be rounded to.
The neighbouring corners
One third-octave either side, and the same 8 kHz corner as every other filter type.
Method and limits. Coefficients follow the RBJ Audio EQ Cookbook, the bilinear transform of the analog prototype prewarped so the corner lands exactly on f0 — which is why 0.00 dB at 8 kHz holds at every sample rate in the table rather than only at low f0/Fs. Shelves fix the slope at S = 1, matching Web Audio's BiquadFilterNode, so Q is not read for those two types. Pole and zero radii are the roots of the quadratic, not sqrt(|a2|). The fixed-point rows model a single shared coefficient scale and no other quantisation: they say nothing about signal-path headroom, limit cycles or the accumulator width your implementation uses, all of which can make a filter that passes this table still misbehave. Nothing on this page is fetched or estimated — it is solved from the type and the frequency in the URL.